Hilbert Transform Instantaneous Amplitude and Phase

Description

Form the analytic signal of a band-limited recording to read its moment-by-moment amplitude envelope, phase and frequency, and compare phases between channels.

The Hilbert transform supplies the imaginary part of the analytic signal. Its magnitude is the instantaneous amplitude (envelope), its angle is the instantaneous phase, and the derivative of phase gives instantaneous frequency. Applied to a band-limited signal dominated by one rhythm, it shows how strongly and at what phase the rhythm is present from moment to moment, which is the basis of envelope analysis, phase synchrony and phase-amplitude coupling. Van Drongelen introduces it to judge which of two simultaneously recorded signals leads: with a small phase difference, the signal with the earlier phase leads. The result is only meaningful when the signal is narrow-band, and a phase lead is a heuristic for sequence, not proof of causation, because a common source or relay chains can produce the same pattern.

Attributes

Loss type
Unmigrated
Stage
Evaluation
Effort
Days

Steps

  1. Band-pass filter the signal so a single rhythm dominates, for example alpha (8-12 Hz) EEG or a respiration band.
  2. Compute the analytic signal (for example MATLAB or SciPy hilbert, which returns the signal plus j times its Hilbert transform).
  3. Take the magnitude as instantaneous amplitude (envelope).
  4. Take atan2 of the imaginary and real parts as instantaneous phase between minus pi and pi.
  5. Differentiate the unwrapped phase and divide by 2 pi times the sample interval for instantaneous frequency.
  6. Compare phases of two channels to estimate lead and lag or phase synchrony, discarding segments with very low amplitude.

Sources

  • Signal Processing for Neuroscientists (van Drongelen, 2018)

Also known as

  • Analytic signal
  • Signal envelope
  • Instantaneous phase
  • Instantaneous frequency
  • Phase lead-lag analysis

Categories

  • Information Theory, Physics & Mathematics