Description
Derives minimum touch target sizes from measured touch-offset distributions for a specific device, posture and population, rather than relying on generic guidelines.
Platform guidelines (44 pt on iOS, 48 dp on Android, 9-10 mm physical) are averages from particular populations and conditions. Empirical derivation measures where real users actually touch when aiming at targets, under the real conditions of use: gloves, motion, one-handed grip, tremor or screen angle. Touch points form a roughly bivariate normal distribution around the intended centre, often systematically offset. The target size needed for a given hit rate follows from the distribution's spread: covering about plus or minus 2 standard deviations gives roughly 95% accuracy in each dimension. Rigour comes from realistic conditions, enough taps per location to estimate offsets across the screen, and reporting sizes for the accuracy required by the task's risk level.
Attributes
- Discipline
- Human Factors & Error
- Loss type
- Latent
- Stage
- Design
- Data
- Quantitative
- Effort
- Weeks
Steps
- Define the conditions of use (device, mount angle, gloves, posture, motion, user population) and the required accuracy (for example 99% for irreversible actions, 95% for routine).
- Build a calibration task presenting crosshair targets at a grid of at least 9-25 screen locations.
- Collect at least 20 taps per location per participant from 12-20 participants under realistic conditions.
- Compute mean offset vectors and standard deviations in x and y for each location.
- Derive target size as the width covering the required proportion of the distribution (about 4 SD for 95%, 5.2 SD for 99%) and apply location-specific offset correction where offsets exceed 1 mm.
- Validate derived sizes in a task-level test with fresh participants and compare error rates against guideline sizes.
Sources
- Clark, J., Designing for Touch (2015)
- Shneiderman, B. & Plaisant, C., Designing the User Interface
- Touch IT
- Gopinath, V., Methods Atlas
- Designing for Touch (Josh Clark)
- Shneiderman & Plaisant
- Methods Atlas (Gopinath)
- The Inquiry Series, Ch 3 — The Ballistics of the Human Body — Fitts' Law & Motor Control
Also known as
- Touch target calibration study
- Empirical target sizing
- Touch accuracy calibration
Categories
- Accessibility
- Human Factors & Error